New version of the Tracker Pro TDR is available!
We are pleased to announce a new version of Tracker Pro TDR is now available on European market and ready for shipments.
Tracker Pro V3

The new V3 model the Tracker Pro TDR has been chosen to replace all the existing models of the Tracker Pro series TDR. It is dedicated to find faults in metallic cables as well as district heating pipelines troubleshooting. As compared to the Tracker Pro V2 model, the major difference is the increased testing range up to 16 km (cables) or 19km (pre-insulated district heating pipelines).
Typical functionality of the Tracker Pro V3 TDR is:
- the most modern TDR technology based on high frequency energy test pulses
- locates faults (cable impedance discontinuities) for most of metallic cable types
- long testing range up to 16km on coax cables or 19km on district heating pipelines
- detects faults at very short distances – less than 1m with a 5ns pulse width
- high resolution large color touch LCD screen
- Auto-Search mode for ease of operation
- IFD (Intermittent Fault Detection) feature
- three measurement cursors and multiple marking system
- intuitive interface combined with accurate diagnose & locating of multiple events
- unique „one-touch storage of all pulse width” Tracker Store System for 60 network tests
- Bluetooth 4 and USB connectivity to tablets and smartphones
- splash proof USB connection and Tracker View PC software at standard delivery
- updates of the Tracker Pro’s operating system & Tracker View software via internet for free
- increased operating time of the internal battery exceeding 9 hours in standard conditions
- rugged and field tested case



Technical Data:
Maximum testing range: 16km (at VOP 85%) or 19km (at VOP 93%)
Distance Accuracy:
2-50 ns pulses – 0,5ns resolution, max distance 3,962 meters @ 85% VOP
100 – 500 ns pulses – 1 ns resolution, max distance or 7,930 m @ 85% VOP
1000 – 2000 ns pulses – 2 ns resolution, max distance 15,850 m @ 85% VOP)
Display: 7” LCD color touchscreen display (800 x 480)
Output Signal: Pulse Widths: 2 nsec, 5 nsec, 20 nsec, 50 nsec, 100 nsec, 300ns, 500 nsec, 1000ns and 2000ns
Note, due to high frequency energy of the pulses, the min. effective test range of 2ns or 5nsec pulse is less than 1m!
Power: Battery: Internal, rechargeable, 8 cell 4200 mAh Nickel metal hydride
Charging source: External 18VDC transformer, 1000mA
Operating time: greater than 9 hours, continuous in standard brightness display mode
Horizontal Resolution: 3cm
Vertical Resolution: 14 bits at 193 dots
Internal Memory: Store up to 60 multi-pulse waveforms files in the instrument’s memory
Input Protection: 400 V (AC + DC) from DC to 400 Hz, decreasing to 10 V at 1 MHz
Filtering: 1x, 2x, 4x, 8x, x16, 32x, 64x
Vertical Gain: 1x/4x, 2x/8x, 4x/16x, 8x/32x, 16x/64x, 32x/128x
VOP Range: 40% – 99%
Connectivity: USB port, internal Bluetoooth 4 modem
Weight: 1,7 kg
Physical dimensions: width 21.4cm x depth 17.2cm x height 9.8cm
Operating temperature: 0º C – 50º C
Storage temperature: -20º C – 60º C
Humidity: 95% maximum relative, non-condensing